Vers. 291020
21
MENU GENERAL SETTINGS
These are general settings that apply to all programs.
SCREEN 1/4
1-
MODEL: it shows the screwdriver model the unit has detected on the connection. (The grey
box is not editable).
2-
SERIAL NUMBER: it shows the serial number of the screwdriver the unit has detected on
the connection. (The grey box is not editable).
3-
NUMBER OF CYCLES: number of cycle of the connected screwdriver.
4-
TEMPERATURE: it shows the temperature on the external casing that the unit reveals in
real time. Exceeding the temperature of 40° C activates the temperature protection,
preventing the screwdriver from working, as soon as the temperature returns below 37° C
the error is reset and the screwdriver can continue working.
5-
FATc: it is the calibration value of the transducer (available also in the calibration certificate
of the tool). This value cannot be changed as it is protected by a Service Passcode. Pressing
the grey box, it’s possible to enter the FATC MODIFICATION menu where you can change
the value using the Service password. By increasing the value the resulting torque will
decrease; if the value decreases, the resulting torque will increase. Should you need to
change this parameter, please contact first Kolver.