Vers. 062721
15
TorqueMinOverMaxLim
In angle control: the minimum torque set in the program is
equal or higher than the maximum torque already set.
In torque control: the minimum torque set in the program
is equal or higher than the target torque already set.
RevTorqueOverMax
The reverse torque of this program is higher than the
maximum torque of the screwdriver.
RevSpeedOverMax
The reverse speed is higher than the maximum allowed by
the screwdriver.
RevSpeedUnderMin
The reverse speed is lower than the minimum allowed by
the screwdriver.
If the connection with the screwdriver is successful, the main screen will be displayed and
the screwdriver will be ready for work.
Connect a thumb drive on the USB-A port (the larger USB port) to automatically save all
screwdriving results on a text file.