MAINTENANCE PLAN
188
WEAM009500
4.8.2 MAINTENANCE INTERVALS IN CASE OF USE OF THE HYDRAULIC
BREAKER
The hydraulic oil used in the machines provided with demolition hammer deteriorates more quickly than the oil
used in normal digging machines, therefore it is advisable to respect the following maintenance plan.
4.8.2.a
CHANGING THE HYDRAULIC OIL FILTER
In new machines, change the filter after the first 100÷150 hours of
operation and for the successive changes keep to the indications
given in the table on the right.
If the machine contains synthetic biodegradable oil type HEES,
the filter must be changed after the first 50 hours of operation.
4.8.2.b
CHANGING THE HYDRAULIC OIL
Change the hydraulic oil in the tank according to the intervals indi-
cated in the table on the right.
On machines containing synthetic biodegradable oil type HEES,
change the oil after the first 500 hours of operation and for the
successive changes keep to the indications given in the table on
the right.
0
20
40
60
80
100
500
2000
Breaker operating ratio (%)
Replacement interval (H)
Replacement interval
for hydraulic oil
RKA1334E
1500
1000
Replacement
interval for element
Summary of Contents for PC26MR-3
Page 2: ......
Page 19: ...SAFETY AND ACCIDENT PREVENTION 17 ...
Page 62: ...60 THIS PAGE WAS INTENTIONALLY LEFT EMPTY ...
Page 63: ...THE MACHINE AND ITS OPERATIONS 61 ...
Page 170: ...168 THIS PAGE WAS INTENTIONALLY LEFT EMPTY ...
Page 171: ...MAINTENANCE 169 ...
Page 226: ...224 THIS PAGE WAS INTENTIONALLY LEFT EMPTY ...
Page 227: ...TECHNICAL SPECIFICATIONS 225 ...
Page 234: ...232 THIS PAGE WAS INTENTIONALLY LEFT EMPTY ...
Page 235: ...AUTHORISED EQUIPMENT 233 ...
Page 250: ...248 THIS PAGE WAS INTENTIONALLY LEFT EMPTY ...
Page 251: ......
Page 252: ... 2008 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 01 2008 ...