10-89
WB97S-5
STRUCTURE AND FUNCTION
PPC VALVES
BACKHOE RH PPC VALVE
Port 1 -
To control valve (Port PB4) (raise boom)
Port T -
To hydraulic tank
Port 4 -
To control valve (Port PA5) (dump bucket)
Port 3 -
To backhoe control valve (Port PA4) (lower boom)
Port P -
To solenoid valve group (VBH port)
Port 2 -
To control valve (Port PB5) (curl bucket)
RKZ10260
View A
A
4
T
1
P
2
3