TESTING AND ADJUSTMENTS
WB97S-5
20-30
BRAKING SYSTEM CHECKS
7 -Hold the pressure on the pedal for at least 2 minutes and
verify that pressure and pedal position remain
unchanged.
a
If the position of the pedal needs to be changed in
order to hold the pressure, then the loss of pressure
is to be blamed on leaks inside the pump, and in this
case the pump needs to be changed. To confirm
whether this is the case, check the oil. If a leak
condition exists, the oil will be stirred.
8 -Repeat for the other pump.
•
Checking the braking groups for leaks.
1 -Disconnect the delivery hose (1) from the braking group
that is being inspected.
2 -Connect a suitable tool between the delivery hose (1)
and the braking group.
a
Check to ensure that the pressure tap (8) is installed
between the braking group and the cut out valve (9).
3 -Connect a pressure gauge
E2
(250 bar) to the tool
pressure tap and open the cut out valve (9).
4 -Operate the brake pump and pressurize the circuit to
150
±
55 bar maximum.
5 -Hold the pressure while simultaneously closing the
valve (9) to keep the braking circuit that is being
inspected under pressure.
6 -Release the brake pedal and monitor pressure gauge
E2
for two minutes.
a
If the pressure reading changes in the negative,
then there is a brake piston seal failure.
k
Further evidence of leak is an increase in the level
of oil in the axle, and the fact that the oil is stirred as
a result. Replace all sealing rings in the various
axle sections and completely change the
lubricant.
7 -Repeat the test for the other braking group using the
same procedure as above.
8 -Restore the braking circuit to operating condition.
k
When checks and repair (if any) are complete,
bleed the air from the braking groups (See
" B L E E D I N G A I R F R O M C I R C U I T S -
ELIMINATING RESIDUAL PRESSURE").
RKZC7910
E2
1
9
8
Summary of Contents for WB97S-5
Page 1: ...WEBM007500 WB97S 5 BACKHOE LOADER SERIAL NUMBER F00003 and up WB97S 5 SHOP MANUAL ...
Page 2: ......
Page 4: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 48: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 144: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 146: ......
Page 161: ...TESTING AND ADJUSTMENTS WB97S 5 20 17 NORMAL OR STANDARD TECHNICAL DATA Fig S RKZ10830 ...
Page 264: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 400: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 508: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ......
Page 581: ...40 15 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE RKZ09071 C C B B A A AE AE X View X ...
Page 589: ...40 23 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE ViewX RKZ09591 C C B B A A AE AE ...
Page 603: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 610: ......
Page 611: ...90 1 WB97S 5 90 OTHER ELECTRICAL DIAGRAM STANDARD VERSION 3 ...
Page 612: ......
Page 614: ......
Page 615: ......
Page 616: ... 2006 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 06 2006 ...