TESTING AND ADJUSTMENTS
WB97S-5
20-35
CHECKING THE SETTING OF MAIN RELIEF AND SECONDARY
CHECKING THE SETTING OF MAIN RELIEF AND SECONDARY
VALVES
•
Checking the operating pressure
of the unloading valve
1 -Connect a pressure gauge
E1
(60 bar) to the pressure
tap
P1C
on the pump.
2 -Start the engine and run the engine at low idling with all
levers in neutral position.
RKZC3260
P1C
E1
3 -In this condition, check the pressure in the hydraulic
circuit.
a
Normal pressure: 41±4 bar
a
The unloading valve cannot be pressure set; if
pressure changes from its normal value, replace the
valve.
•
Checking main relief valve setting
a
Test conditions:
•
Engine: at operating temperature.
•
Hydraulic oil: 45-55 °C
•
Working brakes applied
1 -Connect a pressure gauge
E3
(600 bar) to pressure tap
P1C
of the pump.
RKZC3270
P1C
E3
2 -Start the engine, move the hand accelerator lever to full
throttle and check setting pressure for main relief valve
by forcing the shovel arm raise movement the full travel
span.
a
Nominal pressure: 235–260 bar
a
If the main relief valve pressure does not
correspond to the nominal pressure value, it must
be re-set (For details, see "SETTING THE MAIN
R E L I E F V A L V E S A N D T H E R E D U C I N G
VALVES").
Summary of Contents for WB97S-5
Page 1: ...WEBM007500 WB97S 5 BACKHOE LOADER SERIAL NUMBER F00003 and up WB97S 5 SHOP MANUAL ...
Page 2: ......
Page 4: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 48: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 144: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 146: ......
Page 161: ...TESTING AND ADJUSTMENTS WB97S 5 20 17 NORMAL OR STANDARD TECHNICAL DATA Fig S RKZ10830 ...
Page 264: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 400: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 508: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ......
Page 581: ...40 15 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE RKZ09071 C C B B A A AE AE X View X ...
Page 589: ...40 23 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE ViewX RKZ09591 C C B B A A AE AE ...
Page 603: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 610: ......
Page 611: ...90 1 WB97S 5 90 OTHER ELECTRICAL DIAGRAM STANDARD VERSION 3 ...
Page 612: ......
Page 614: ......
Page 615: ......
Page 616: ... 2006 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 06 2006 ...