TESTING AND ADJUSTMENTS
WB97S-5
20-37
CHECKING THE SETTING OF MAIN RELIEF AND SECONDARY
•
Checking secondary valve setting
(for boom raise movement)
a
Test conditions:
•
Engine: at operating temperature.
•
Hydraulic oil: 45-55 °C
•
Working brakes applied
1 -Set the machine with arm in vertical position and with
bucket on level ground leaned on the side.
2 -Stop the engine and release residual hydraulic
pressures.
RKZ10900
3 -Disconnect the hose (1) and connect a tee fitting (2) with
adapter.
4 -Connect a pressure gauge
E3
(600 bar) to the adapter.
RKZC7960
E3
2
1
5 -Start the engine, connect a weight of approx. 1500 kg to
the bucket, and fully lower the outriggers.
RKZ10910
6 -Slowly extend the arm and boom and take the pressure
when the boom lowers.
a
Normal pressure: 320–360 bar
RKZ10920
Summary of Contents for WB97S-5
Page 1: ...WEBM007500 WB97S 5 BACKHOE LOADER SERIAL NUMBER F00003 and up WB97S 5 SHOP MANUAL ...
Page 2: ......
Page 4: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 48: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 144: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 146: ......
Page 161: ...TESTING AND ADJUSTMENTS WB97S 5 20 17 NORMAL OR STANDARD TECHNICAL DATA Fig S RKZ10830 ...
Page 264: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 400: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 508: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ......
Page 581: ...40 15 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE RKZ09071 C C B B A A AE AE X View X ...
Page 589: ...40 23 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE ViewX RKZ09591 C C B B A A AE AE ...
Page 603: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 610: ......
Page 611: ...90 1 WB97S 5 90 OTHER ELECTRICAL DIAGRAM STANDARD VERSION 3 ...
Page 612: ......
Page 614: ......
Page 615: ......
Page 616: ... 2006 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 06 2006 ...