TESTING AND ADJUSTMENTS
WB97S-5
20-50
ANALYSIS OF CAUSES HYDRAULIC DRIFT
ANALYSIS OF CAUSES HYDRAULIC DRIFT
a
If working attachments have a hydraulic drift, it is
necessary to check if reason is due to cylinders gaskets
or to control valve.
a
All testing conditions:
•
Engine: at operating temperature
•
Hydraulic oil: 45–55 °C
•
Removal and installation of pipes only after remain
pressure removal.
FRONT EQUIPMENT
•
Shovel raise check
1 -Put the machine with the shovel teeth on blocks “
A
” of
about 10 cm and in vertical position in relation to the
ground.
2 -Stop the engine and release residual hydraulic
pressures.
3- Disconnect pipes (1) and (2) from lift cylinders (3) and
plug them.
4 -Plug cylinders, base side, and apply a temporary pipe,
head side, to catch possible oil leakage.
5 -Start the engine and curl shovel until the teeth are in tilt
position by about 10°.
6 -Stop the engine and check shovel link position for 5
minutes.
•
If bucket link has no lowering movement, drift is due
to control valve.
To test the individual cylinders, proceed as follows:
7 -Carry out with shovel a dump movement to let teeth lean
on ground in vertical position.
8 -Remove from one of the cylinders the plug fitted on the
cylinder bottom side in Phase 4.
9 -Start the engine and retract the shovel until to bring the
teeth in tilt position of about 10° towards upper.
10 -Stop the engine and check the shovel position for 5
minutes.
•
If shovel link has a lowering movement, drift is due to
gaskets of plugged cylinder.
11 -Repeat operation from stage 8 to stage 10 to check the
other cylinder.
RKZC3440
A
RKZC3380
1
3
2
RKZC3450
Summary of Contents for WB97S-5
Page 1: ...WEBM007500 WB97S 5 BACKHOE LOADER SERIAL NUMBER F00003 and up WB97S 5 SHOP MANUAL ...
Page 2: ......
Page 4: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 48: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 144: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 146: ......
Page 161: ...TESTING AND ADJUSTMENTS WB97S 5 20 17 NORMAL OR STANDARD TECHNICAL DATA Fig S RKZ10830 ...
Page 264: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 400: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 508: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ......
Page 581: ...40 15 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE RKZ09071 C C B B A A AE AE X View X ...
Page 589: ...40 23 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE ViewX RKZ09591 C C B B A A AE AE ...
Page 603: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 610: ......
Page 611: ...90 1 WB97S 5 90 OTHER ELECTRICAL DIAGRAM STANDARD VERSION 3 ...
Page 612: ......
Page 614: ......
Page 615: ......
Page 616: ... 2006 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 06 2006 ...