40-27
WB97S-5
STANDARD MAINTENANCE
CONTROL VALVE
Unit: mm
No. Check item
Criteria
Remedy
Standard size
Repair limit
Replace
spring
Free
installed
x Øe
Installed
length
Installed
load
Free
installed
Installed
load
1
Pressure compensation valve
spring
(Shovel arm, backhoe bucket,
boom, shovel, boom swing, jig
arm, 4 in 1 bucket)
15.4x6
8
7.44N
–
5.96N
2
Pressure compensation valve
spring
(arm)
31.4x14.4
21.8
63.7N
–
51.0N
3
Pressure compensation valve
spring.
(Boom swing, backhoe bucket)
18.9x8.4
15
15.7N
–
12.5N
4
Pressure compensation valve
spring.
(Front bucket)
37.1x8.6
24
34.3N
–
27.4N
5
Pressure compensation valve
spring.
(boom, shovel arm
jig arm, 4 in 1 bucket)
20x8.4
15
4.32N
–
3.45N
6
Check valve spring
27.2x6.9
21
4.70N
–
3.76N
7
Check valve spring
27.2x6.9
22
3.92N
–
3.14N
8
Check valve spring
21.9x5
15.8
1.96N
–
1.57N
9
Check valve spring
11.3x4.3
7.5
1.72N
–
1.38N
Summary of Contents for WB97S-5
Page 1: ...WEBM007500 WB97S 5 BACKHOE LOADER SERIAL NUMBER F00003 and up WB97S 5 SHOP MANUAL ...
Page 2: ......
Page 4: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 48: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 65: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 144: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 146: ......
Page 161: ...TESTING AND ADJUSTMENTS WB97S 5 20 17 NORMAL OR STANDARD TECHNICAL DATA Fig S RKZ10830 ...
Page 264: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 400: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 508: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ......
Page 581: ...40 15 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE RKZ09071 C C B B A A AE AE X View X ...
Page 589: ...40 23 WB97S 5 STANDARD MAINTENANCE CONTROL VALVE ViewX RKZ09591 C C B B A A AE AE ...
Page 603: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 610: ......
Page 611: ...90 1 WB97S 5 90 OTHER ELECTRICAL DIAGRAM STANDARD VERSION 3 ...
Page 612: ......
Page 614: ......
Page 615: ......
Page 616: ... 2006 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 06 2006 ...