DISCONNECT AND CONNECT PUSH-PULL TYPE COUPLER
REMARK
• Loosen the oil filler cap of the hydraulic tank slowly to release the remaining pressure in the hydraulic tank.
• Provide an oil container to receive oil since some hydraulic oil flows out when the hose is disconnected even
after the remaining pressure is released from the hydraulic tank.
METHOD FOR DISCONNECTING AND CONNECTING TYPE 1 PUSH-PULL TYPE
COUPLER
Disconnection
1.
Hold adapter (1), and push hose joint (2) into mating
adapter (3).
REMARK
• Push it in approximately 3.5 mm.
• Do not hold rubber cap portion (4).
2.
While having adapter (3) inserted into hose side joint (2),
insert rubber cap (4) to adapter (3) side until it clicks.
3.
Hold hose adapter (1) or hose (5), and pull it out.
REMARK
Provide an oil container to receive a quantity of hydraulic
oil which may flow out.
Connection
1.
Hold hose adapter (1) or hose (5), and insert it in mating
adapter (3), aligning the axis.
REMARK
Do not hold rubber cap portion (4).
DISCONNECT AND CONNECT PUSH-PULL TYPE COUPLER
00 INDEX AND FOREWORD
00-54
PC210LC-11
Summary of Contents for 500001
Page 1: ...HYDRAULIC EXCAVATOR SEN06516 01 PC210LC 11 SERIAL NUMBERS 500001 and up ...
Page 2: ...Find manuals at https best manuals com ...
Page 3: ...00 INDEX AND FOREWORD PC210LC 11 00 1 Find manuals at https best manuals com ...
Page 61: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com ...