An abnormality has occurred in the tilt sensor connected to the
bucket if the error screen shown in the figure is displayed.
The signal from tilt sensor cannot be received for 3 seconds or
more.
Tap RETURN button to stop the calibration, and return to the
menu screen in this case.
After the error is resolved, perform the calibration again.
PROCEDURES OF CALIBRATION OF BUCKET TOOTH
Perform the bucket tooth calibration when tooth is worn and
tooth tip position changes or tooth is replaced.
Place the tooth tip to the point (1) whose coordinates are al-
ready known in daily check. Set the bucket to the posture in the
figure, and check the coordinates of the tooth tip.
If the error is in the height direction of coordinates, bucket tooth
may be worn. In that case, perform bucket tooth calibration.
METHOD FOR STARTING APPLICATION FOR CALIBRATION OF BUCKET
TOOTH
1.
Tap the menu button on the control box.
Main menu screen is displayed.
SETTING
CONTROL BOX
7-175