E(AR)-3
Adjustment
Content of Function
Initial Value
Range
Remark
Automatic power-off set
When the travel or cargo-handling is not operated for a
certain period of time (15 minutes), the power is
automatically shut down.. It sets this function.
1
:
Valid
0: Invalid
1: Valid
FR link relay drive travel
It sets the condition for signal outputted from CN1-D1
terminal No.5 of travel controller.
2
0
~
3
0
:
No output 1: Output at forward 2: Output at
backward
4: Output at other than neutral
Slope regeneration ON/OFF selection
It sets ON/OFF of creeping travel on the down-slope.
When the FP switch is set to ON, the speed is
controlled to 1 – 2km/h.
1
0:OFF
1:ON
Cargo-handling System Parameter Set Function
Adjustment Item
Content of Function
Initial Value
Range
Remark
*
U mode
Cargo-handling power
It sets the torque property of travel power.
2
1
~
3
1:L/2:M/3:H
Fixed value
L:2, M:2 ,H:3
*
U mode
Lift 1 speed
It sets the lift 1 speed.
100
(%)
1
~
100
(%)
1: Low speed
100: High speed
The optimum range
〔
60
~
100%
〕
Fixed value
L/M/H
100 each
*
U mode
Lift 2 speed
It sets the lift 2 speed.
100
(%)
1
~
100
(%)
1: Low speed 100: High speed
The optimum range
〔
60
~
100%
〕
Fixed value
L/M/H
100 each
*
U mode
Tilt speed
It sets the tilt speed.
100
(%)
30
~
100
(%)
30: Low speed
100: High speed
Fixed value
L/M/H
100 each
*
U mode
Reach speed
It adjusts the speeds of reach-out and reach-in.
100
(%)
40
~
100
(%)
40: Low speed
100: High speed
ATT1 speed
It sets the attachment 1 speed.
90
(%)
30
~
100
(%)
30: Low speed
100: High speed
ATT2 speed
It sets the attachment 2 speed.
100
(%)
30
~
100
(%)
30: Low speed
100: High speed
Lift interrupt
It limits the cargo-handling operation when the battery
remaining is below 20% and warns the operator to
recharge.
0(Valid)
0
:
Invalid
1
:
Valid
FR link relay drive cargo-handling
It sets the condition for signal outputted from CN1-P
terminal No.5 of cargo-handling controller.
1
0
~
3
0: No output 1: Output at forward 2: Output at
backward 4: Output at other than neutral
Lift lever open property
It sets the lift speed control that responds to the lift
lever operation.
1
1
~
3
1: Lift property in proportional to the lift lever operation
(standard)
2: Lift property in the middle of 1 and 3
3: Micro-switch(ON/OFF) 2 step control
Speed selection at simultaneous operation
It selects the reach speed when the lift and other lever
are simultaneously operated.
0
0
:
Top priority
1
:
Least priority
0: Reach speed becomes equivalent to the existing
one
1: Reach speed becomes lower than the existing one.
Summary of Contents for AE50
Page 2: ...J 1 LYM2008K0099J...
Page 16: ...J AR 1...
Page 23: ...J AR 8 0 0 1 RL 1 RS RW 1 0 0 1 RL 1 RS RW 0 ON OFF 0 OFF 1 ON SW ON 0 OFF 1 ON...
Page 26: ...E 1 LYM2008K0099E Parameter Sheet for AE50 AM50...
Page 40: ...E AR 1 Parameter Sheet for AR50...
Page 50: ...CN 1 LYM2008K0099CN for AE50 AM50 for AE50 AM50 for AE50 AM50 for AE50 AM50...
Page 60: ...CN 11 ON 1 0 OFF 1 ON MODE 1 0 OFF 1 ON 1 0 OFF 1 ON 1 0 OFF 1 ON 1 0 OFF 1 ON...
Page 62: ...CN AR 1 for for for for AR50 AR50 AR50 AR50...
Page 69: ...CN AR 8 1 0 1 0 1 RL 1 RS RW 1 2 0 1 0 1 RL 1 RS RW 0 ON OFF 1 0 OFF 1 ON 1 0 OFF 1 ON...
Page 72: ...RU 1 LYM2008K0099RU AE50 AM50...
Page 76: ...RU 5 0 1 1 0 0 1 3 1 240 30 5 240 OFF 5 5 240 F R 0 0 F R 1 0 1 0 0 1 0 1...
Page 77: ...RU 6 0 00 50 00 c 2 5 00 20 00 2 0 2 0 K 2 AE50 AM50 1 0 50 3 00 0 10 0 40...
Page 86: ...RU AR 1 AR50...
Page 94: ...RU AR 9 1 0 1 0 1 RL 1 RS RW 1 2 0 1 0 1 RL 1 RS RW 0 1 0 1 1 0 1...