NOTICE
Even if the regeneration is disabled, KDPF soot accumula-
tion caution lamp (1) lights up if soot is accumulated and
the manual stationary regeneration is required. If KDPF
soot accumulation caution lamp lights up, move the ma-
chine to a safe place and perform manual stationary regen-
eration.
If the operation is continued without performing the man-
ual stationary regeneration, it may cause the failure of
KDPF or the engine.
While regeneration is not being performed: Setting for the regeneration disable
(When the aftertreatment devices regeneration pilot lamp is lit on the standard screen)
1.
Press function switch F6 on the standard screen.
2.
Operate function switches F1 and F2 to select the After-
treatment Devices Regeneration menu (C) to display the
Aftertreatment Devices Regeneration screen.
3.
Select the regeneration disable and press function switch
F6, then the regeneration function is disabled and the re-
generation cannot be performed.