The inducement strategy progresses in 4 levels, “Warning”,
“Continuous Warning”, “Low level Inducement”, and “Severe In-
ducement”. The Inducement strategy includes visual alert by
the Engine system caution lamp (1), DEF system caution lamp
(2), and Action Level displayed on the machine monitor (3), au-
dible alert by a buzzer and stepwise engine power deration that
advances to speed limitation to low idle. Engine power deration
starts with Action Level “L03 (Warning, Continuous Warning
and Low level Inducement)” and advances to further deration
when “L04 (Severe Inducement)” is displayed. Once the sys-
tem advances to “Severe Inducement”, the engine power will
be further derated. If “L03” is displayed, move the machine to a
safe place and contact your Komatsu distributor.
The content of the warning can be checked on the “SCR Information” screen of the user menu.
Perform the following procedure.
Press F6 on the standard screen to display the “SCR Informa-
tion” screen of the user menu.
If either the parking brake lever and work equipment lock lever
are set to LOCK position or the joystick (steering, directional
and gear shift lever) is in NEUTRAL position for over 3 sec-
onds, “SCR Information” screen of the user menu will pop up
automatically while the Urea SCR system is in Inducement.
“SCR Information” screen displays remaining time to the next
Inducement status in the column (6), and information on the
Urea SCR System condition (4), and the current status of In-
ducement (5).
• Warning:
The audible alert sounds in short and sharp beeps.
The Engine system caution lamp (1) lights up in red.
The action level “L03” lights up in red at action level dis-
play (3).
Press F6 to display the “SCR Information” screen.