1.
Open inspection cover (1) on the side of the battery cover
on left side of the machine.
2.
Use a wet cloth to clean the area around the electrolyte
level lines and check that the electrolyte level is between
UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.) lines.
3.
When the electrolyte level is below the center between
UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.), remove
vinyl sheet (2) installed over the battery.
4.
Remove cap (3) immediately and add purified water (ex-
ample: commercially available battery liquid) up to UPPER
LEVEL (U.L.)
5.
After adding the purified water, tighten cap (3) securely.
REMARK
If the purified water is added to above UPPER LEVEL (U.L.) line, remove the fluid by using a syringe to lower
the level to UPPER LEVEL (U.L.) line. Neutralize the removed electrolyte with baking soda (sodium bicarbon-
ate), then flush it away with a large amount of water. If necessary, consult your Komatsu distributor or a battery
manufacturer.
METHOD FOR CHECKING ELECTROLYTE LEVEL WHEN IT IS IMPOSSIBLE TO
CHECK FROM SIDE OF BATTERY
If it is impossible to check the electrolyte level from the side of the battery, or there is no UPPER LEVEL line on
the side of the battery, check as follows.