7.
Check that the work equipment lowers to the ground.
If the work equipment goes down under its weight and contacts the ground, the accumulator is normal.
If the work equipment does not go down or stops in midway, the charged pressure of the gas in the accumulator
for the hydraulic circuit has probably dropped.
Ask your Komatsu distributor for inspection.
After completion of the inspection, set the work equipment lock lever to LOCK position and turn the starting
switch to OFF position.
METHOD FOR RELEASING PRESSURE IN HYDRAULIC CIRCUIT
1.
Lower the work equipment to the ground.
2.
Set the parking brake lever and work equipment lock lever
to LOCK positions.
3.
Stop the engine.
4.
Turn the starting switch to ON position (B).
5.
Set the work equipment lock lever to FREE position (F).
6.
Operate the blade control lever and ripper control lever
fully to the front, rear, left, and right to release the pressure
from the hydraulic circuits.
7.
Set the work equipment lock lever to LOCK position, then
turn the starting switch to OFF position (A).
METHOD FOR CHECKING AND ADJUSTING ENGINE VALVE CLEARANCE
Special tools are necessary for inspection and maintenance. Ask your Komatsu distributor to perform this work.
METHOD FOR REPLACING KCCV FILTER ELEMENT
k
k
WARNING
After the engine has been operated, all of parts are still very hot. Do not replace the filter element imme-
diately. Perform it after each portion is cooled.
MAINTENANCE
MAINTENANCE PROCEDURE
4-73
Summary of Contents for D155AX-8E0
Page 2: ......
Page 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Page 24: ......
Page 312: ......
Page 397: ...SPECIFICATIONS 5 1...
Page 404: ......
Page 405: ...REPLACEMENT PARTS 7 1...