Foreword and general information
Handling of electric equipment
2 6
HB205-1, HB215LC-1
00-26
5) Push lock type (3)
q
95/125/140/170/12V140 series
Disconnection
While pressing lock (E) of the connector, pull
out connector (5) in the direction of the arrow.
Example) Fuel pressure sensor in common
rail: PFUEL etc.
(AMP-3)
Example) Injection pressure control valve of
fuel supply pump: PCV
(SUMITOMO-2)
Examples) Speed sensor of fuel supply
pump: G
(SUMITOMO-3)
a
Pull the connector straight up.
Connection
Insert the connector straight until it "clicks".
6) Turn-housing type (Round green
connector)
q
140 series
Example) Intake air pressure sensor in
intake manifold.
(CANNON-04): PIM, etc.
Disconnection
1] Turn housing (H1) in the direction of the
arrow.
a
When connector is unlocked, housing
(H1) becomes heavy to turn.
2] Pull out housing (H1) in the direction of
the arrow.
a
Housing (H1) is left on the wiring har-
ness side.
Connection
1] Insert the connector to the end, while
setting its groove.
2] Turn housing (H1) in the direction of the
arrow until it "clicks".