REMARK
A circuit breaker is a circuit protection device installed to a high-voltage current circuit.
Similarly to an ordinary fuse, it protects electrical parts and wiring from burning out caused by abnormal current.
It can be operated again without replacing the circuit breaker itself after the abnormal part has been corrected.
No.
Capaci-
ty
Name of circuit
(1)
60 A
Continuous power supply for engine control
(2)
105 A
Power supply for fuse box
When the circuit breaker operates
1.
Turn the starting switch to OFF position.
2.
Push in the reset button after a lapse of 5 to 10 minutes of cutting off.
3.
Check the reset button.
Operating effort of the reset button becomes larger when the circuit is open than when the circuit is not
open.
If the operating effort is still large after the reset button has been pushed in, the electrical circuit may be
open. In such case, ask your Komatsu distributor for repair.
DUST INDICATOR
This device indicates clogging of the air cleaner.
Depending on the degree of clogging of the element, red line
(1) appears in the transparent portion.
If red line (1) indicates 7.5 kPa {0.076 kg/cm
2
}, clean the ele-
ment immediately.
After cleaning, press the top part (2) of the indicator, and return
the red line (1) to its original position.
BODY PIVOT PINS
k
k
WARNING
To inspect the machine with the dump body lifted, set the dump lever to “HOLD” and lock with knob.
Then, use the body pivot pin.
OPERATION
EXPLANATION OF COMPONENTS
3-129
Summary of Contents for HD325-8
Page 2: ......
Page 13: ...FOREWORD INTRODUCTION 1 11 ...
Page 25: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 3 ...
Page 26: ...SAFETY LABELS SAFETY 2 4 ...
Page 340: ......
Page 424: ......
Page 425: ...SPECIFICATIONS 5 1 ...
Page 429: ...ATTACHMENTS AND OP TIONS Before reading this chapter read and understand the SAFETY 6 1 ...
Page 447: ...REPLACEMENT PARTS 7 1 ...
Page 463: ......