115
USING THE WORK EQUIPMENT
3.12.5 CHANGING THE BUCKET
DANGER
•
When the coupling pins are removed or installed, chips
may come off; always use gloves, goggles and helmet.
•
The change of the equipment must be carried out by two
persons, who must decide together the words and signals
to use during operations.
•
Do not use your fingers to center the holes, since they may
be injured or even cut in case of sudden or uncontrolled
movements.
•
The described procedures are valid also for the coupling of
the mechanical constraints of the optional equipment.
1 - Position the bucket on a level surface, directing it so that the
flat part of its back rests on the ground.
2 - Remove first the tie rod pin (1) and then the arm connection
pin (2).
3 - Change the bucket, taking care to clean the pins, the bushings
and the seals perfectly and to grease the pins slightly before
reinstalling them.
IMPORTANT
☞
•
Install first the arm connection pin, making sure that the
seals are in good conditions.
4 - Put back all the safety pins (3) and lubricate by means of the
appropriate grease nipple.
RWAA1060
2
1
3
3