MAINTENANCE PLAN
145
4.7.1 WHEN REQUIRED
4.7.1.a
CHECKING, CLEANING OR CHANGING THE AIR CLEANER CARTRIDGE
DANGER
•
Remove the air cleaner only after stopping the engine and do not start the engine if the air cleaner is
open.
•
Always wear goggles while cleaning the filter.
IMPORTANT
☞
•
The air filtering system comprises a primary filtering ele-
ment with great capacity and a secondary cartridge that
provides additional safety protection.
The primary element can be cleaned with compressed air,
while the safety cartridge can only be changed.
•
The filtering element must be cleaned when the clogging
warning light (A) positioned on the instrument panel blinks
or comes on completely.
In any case, check the cartridge for any clogging every 50
hours of operation of the machine.
The air cleaner can be reached after opening the engine hood
(see “3.5.1 ENGINE HOOD”).
To clean the primary element, proceed as follows:
1 - Pull the yellow safety device (1) to release the cover.
2 - Rotate the filter cover (2) anticlockwise and remove it.
3 - Extract the main filtering element (3).
4 - Slightly strike the element on the palm of your hand to elimi-
nate the dust and blow compressed air on the inner surface,
keeping the air jet at a distance of approximately 15 cm and
making sure that the pressure does not exceed 4-5 bars.
5 - Carefully clean the inside of the filter casing (4), taking care to
avoid the introduction of foreign matters in the suction duct.
6 - Reassemble the filtering element (3), making sure that it is
correctly positioned in its seat.
RYA15820
00000 00
C
H
F
E
A
1
RWAA12430
2
RWAA12440
3
4
Summary of Contents for PC110R-1
Page 2: ......
Page 19: ...17 SAFETY AND ACCIDENT PREVENTION...
Page 51: ...49 THE MACHINE AND ITS OPERATIONS...
Page 126: ...124 PAGE INTENTIONALLY LEFT BLANK...
Page 127: ...125 MAINTENANCE...
Page 190: ...188 PAGE INTENTIONALLY LEFT BLANK...
Page 191: ...189 TECHNICAL SPECIFICATIONS...
Page 198: ...196 PAGE INTENTIONALLY LEFT BLANK...
Page 199: ...197 AUTHORISED OPTIONAL EQUIPMENT...