MAINTENANCE PLAN
146
7 - Put back the cover (2) and rotate it clockwise, making sure that
the ejector (5) is positioned vertically and at the bottom.
8 - Lock the cover by means of the yellow safety device (1).
IMPORTANT
☞
•
If the clogging warning light comes on after the engine has
started, it is necessary to change the primary filtering ele-
ment and the safety cartridge.
•
Change the primary filtering element after 6 cleaning oper-
ations or after one year. The safety cartridge must always
be changed together with the primary filtering element.
To have a point of reference for the change interval, it is ad-
visable to mark the primary filtering element on every
cleaning operation.
To change the safety cartridge, after removing the primary ele-
ment proceed as follows:
1 - Remove the safety cartridge (6) and reject it.
2 - Carefully clean the inside of the filter casing (4), taking care to
avoid the introduction of foreign matters in the suction duct.
3 - Install a new safety cartridge and a new main filtering element,
making sure that they are correctly positioned in their seats.
4 - Put back the cover (2) and rotate it clockwise, making sure that
the ejector (5) is positioned vertically and at the bottom.
5 - Lock the cover by pushing the yellow safety device (1).
1
RWAA12450
2
5
RWAA12460
6
4
Summary of Contents for PC110R-1
Page 2: ......
Page 19: ...17 SAFETY AND ACCIDENT PREVENTION...
Page 51: ...49 THE MACHINE AND ITS OPERATIONS...
Page 126: ...124 PAGE INTENTIONALLY LEFT BLANK...
Page 127: ...125 MAINTENANCE...
Page 190: ...188 PAGE INTENTIONALLY LEFT BLANK...
Page 191: ...189 TECHNICAL SPECIFICATIONS...
Page 198: ...196 PAGE INTENTIONALLY LEFT BLANK...
Page 199: ...197 AUTHORISED OPTIONAL EQUIPMENT...