MAINTENANCE NOTES
174
WEAM009300
4.2.1.4 KOWA
(KOMATSU OIL WEAR ANALYSIS)
This system requires that oil samples be periodically collected and analysed. This is a preventive maintenance
service, which makes it possible to identify faulty parts or worn machine components timely. It also allows many
failures to be prevented and machine downtime to be reduced.
Many years of experience and the availability of countless data and information allow Komatsu to accurately deter-
mine the conditions of the machine. This also allows us to locate troubles and suggest the most suitable and fast
repair solutions.
The customer immediately receives a report containing the results of the analysis and suggestions for the opera-
tions to be carried out. This low-cost service is very useful and allows customers to save money and avoid many
problems.
KOWA ANALYSIS STAGES
q
Analysis of metal particles
In this stage a ICP (Inductively Coupled Plasma) analyser is
used to measure the density of the metal particles present in the
oil.
q
Measurement of particle quantity
In this stage a PQI (Particle Quantifier Index) machine is used
to measure the quantity of large iron particles present in the oil.
q
Other analyses and measurements
In this stage other aspects, such as the percentage of water or
fuel in the oil and the dynamic viscosity, are analysed.
OIL SAMPLING
q
Collection interval
Every 500 hours: engine and other components
q
Precautions to be taken when sampling the oil
• Make sure that the oil is well mixed before sampling.
• Carry out sampling regularly, at fixed intervals.
• Do not carry out sampling on rainy or windy days, when water or dust can get into the oil.
For further details on KOWA, please contact your Komatsu Dealer.
4.2.1.5 STORING OIL AND FUEL
q
Keep oil and fuel indoors to prevent any water, dirt, or other impurities from getting into them.
Summary of Contents for PC14R-3
Page 2: ......
Page 19: ...SAFETY AND ACCIDENT PREVENTION 17...
Page 61: ...THE MACHINE AND ITS OPERATIONS 59...
Page 171: ...MAINTENANCE 169...
Page 221: ...TECHNICAL SPECIFICATIONS 219...
Page 229: ...AUTHORISED OPTIONAL EQUIPMENT 227...
Page 244: ...242 THIS PAGE WAS INTENTIONALLY LEFT EMPTY...
Page 245: ......
Page 246: ...2007 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 12 2007...