MAINTENANCE PROCEDURES
190
WEAM009300
4.9.1.b
CHECKING THE BATTERY CHARGE LEVEL
WARNING
q
Check the charge level only with the engine at rest.
q
To prevent gas explosions, do not use naked flames, do not smoke and avoid producing sparks due to
short circuits.
q
The battery electrolyte is dangerous; in case of contact with the eyes or skin, rinse with plenty of water
and consult a doctor without delay. The battery is maintenance-free.
IMPORTANT
q
Make sure that the connection terminals are not oxidized; if necessary, clean them and cover them with
anti-oxidation grease.
The battery (1) can be reached after removing the battery housing
(see "3.2.8 BATTERY COVER").
A visual indicator (2) signals, with different colours, the battery
charge level according to the table next to the indicator:
-
Green: optimal charge
-
Gray: the battery needs recharging
-
White: the battery must be replaced.
WARNING
q
If a dry battery is used, check that the electrolyte level is approximately 6 mm above the plate edge; if
necessary, top up using distilled water only.
If, on the contrary, the level is low because some fluid has been spilled, add sulphuric acid, after diluting
it to reach the concentration suitable for the ambient temperature (see "3.5.1.3 BATTERY").
q
It is advisable to add distilled water just before starting work, in order to prevent if from freezing.
q
Before putting back the cell caps, make sure that the breather holes are not clogged.
RKA23070
Summary of Contents for PC14R-3
Page 2: ......
Page 19: ...SAFETY AND ACCIDENT PREVENTION 17...
Page 61: ...THE MACHINE AND ITS OPERATIONS 59...
Page 171: ...MAINTENANCE 169...
Page 221: ...TECHNICAL SPECIFICATIONS 219...
Page 229: ...AUTHORISED OPTIONAL EQUIPMENT 227...
Page 244: ...242 THIS PAGE WAS INTENTIONALLY LEFT EMPTY...
Page 245: ......
Page 246: ...2007 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 12 2007...