MAINTENANCE PLAN
208
4.8.2 MAINTENANCE INTERVALS IN CASE OF USE OF THE HYDRAULIC
BREAKER
In machines equipped with breaker hydraulic oil deteriorates more rapidly than in machines equipped with stand-
ard equipment. When using the breaker, always keep to the following maintenance plan.
4.8.2.a
CHANGING THE HYDRAULIC OIL FILTER
In new machines, change the filter after the first 100–150 hours of
operation and for the successive changes keep to the indications
given in the table on the right.
If the machine contains synthetic biodegradable oil type HEES,
the filter must be changed after the first 50 hours of operation.
(A): Hydraulic fluid filter - replacement interval.
(X): Hydraulic breaker - use percentage (%).
(Y): Change interval (H).
4.8.2.b
CHANGING THE HYDRAULIC OIL
Change the hydraulic oil in the tank according to the intervals indi-
cated in the table on the right.
On machines containing synthetic biodegradable oil type HEES,
change the oil after the first 500 hours of operation and for the
successive changes keep to the indications given in the table on
the right.
(B): Hydraulic oil replacement interval.
(X): Hydraulic breaker - use percentage (%).
(Y): Change interval (H).
0
20
40
60
80
100
(%)
500
2000
(H)
1500
1000
B
Y
X
A
WEAM012405
Summary of Contents for PC16R-3
Page 2: ......
Page 24: ...22 THIS PAGE WAS INTENTIONALLY LEFT EMPTY WEAM012405...
Page 25: ...SAFETY AND ACCIDENT PREVENTION 23 WEAM012405...
Page 79: ...THE MACHINE AND ITS OPERATIONS 77 WEAM012405...
Page 190: ...188 THIS PAGE WAS INTENTIONALLY LEFT EMPTY WEAM012405...
Page 191: ...MAINTENANCE 189 WEAM012405...
Page 244: ...242 THIS PAGE WAS INTENTIONALLY LEFT EMPTY WEAM012405...
Page 245: ...TECHNICAL SPECIFICATIONS 243 WEAM012405...
Page 253: ...AUTHORISED OPTIONAL EQUIPMENT 251 WEAM012405...
Page 286: ...284 WEAM012405...
Page 287: ......
Page 288: ...2017 KOMATSU ITALIA MANUFACTURING S p A All Rights Reserved Printed in Europe 02 2017...