MAINTENANCE PLAN
WEAM012101
211
4.8.2 MAINTENANCE INTERVALS IN CASE OF USE OF THE HYDRAULIC
BREAKER
The hydraulic oil used in the machines provided with demolition hammer deteriorates more quickly than the oil
used in normal digging machines, therefore it is advisable to respect the following maintenance plan.
4.8.2.a
CHANGING THE HYDRAULIC OIL FILTER
In new machines, change the filter after the first 100÷150 hours of
operation and for the successive changes keep to the indications
given in the table on the right.
If the machine contains synthetic biodegradable oil type HEES,
the filter must be changed after the first 50 hours of operation.
(A): Hydraulic fluid filter - replacement interval.
(X): Demolition hammer - use percentage (%).
(Y): Change interval (H)
4.8.2.b
CHANGING THE HYDRAULIC OIL
Change the hydraulic oil in the tank according to the intervals indi-
cated in the table on the right.
On machines containing synthetic biodegradable oil type HEES,
change the oil after the first 500 hours of operation and for the
successive changes keep to the indications given in the table on
the right.
(B): Hydraulic oil replacement interval
(X): Demolition hammer - use percentage (%).
(Y): Change interval (H)
80
60
40
20
0
100 (%)
500
2000
(H)
1500
1000
A
B
Y
X
RKA26170
Summary of Contents for PC18MR-3
Page 2: ......
Page 16: ...14 THIS PAGE WAS INTENTIONALLY LEFT EMPTY...
Page 24: ...22 PAGE INTENTIONALLY LEFT BLANK...
Page 25: ...SAFETY AND ACCIDENT PREVENTION 23...
Page 78: ...76 PAGE INTENTIONALLY LEFT BLANK...
Page 79: ...THE MACHINE AND ITS OPERATIONS 77...
Page 192: ...190 PAGE INTENTIONALLY LEFT BLANK...
Page 193: ...MAINTENANCE 191...
Page 255: ...TECHNICAL SPECIFICATIONS 253...
Page 263: ...AUTHORISED OPTIONAL EQUIPMENT 261...
Page 282: ...280 THIS PAGE WAS INTENTIONALLY LEFT EMPTY...
Page 283: ......
Page 284: ...2010 KOMATSU UTILITY EUROPE S p A All Rights Reserved Printed in Europe 06 2010...