5.
Check that filter removal tool (3) is fully inserted to the end.
Insert the filter to the end where you cannot thrust it in any
further.
6.
Turn filter removal tool (3) in reverse, and remove filter (6).
Filter (6) is removed and you can take it out together with
filter removal tool (3).
If filter (6) cannot be removed from DEF pump, grip filter
removal tool (3), pull it down, then it will be removed.
7.
Slide filter (6) down, and remove spacer (5) from filter re-
moval tool (3).
8.
Pull filter (6) up while pushing in the tip of filter removal
tool (3), and remove it.
9.
Return the removed spacer (5) to filter removal tool (3),
and keep them.
10. Insert a new filter and a new equalizing element into the
bottom of DEF pump, and lightly tighten them with hand.
11. Tighten filter cap (1).
Tightening torque: 20 to 25 Nm {2.0 to 2.5 kgm}
EVERY 4000 HOURS MAINTENANCE
Maintenance for every 100, 250, 500, 1000 and 2000 hours service should be performed at the same time.
MAINTENANCE
MAINTENANCE PROCEDURE