REMARK
If heavy-duty operation is performed for more than 30 minutes
with the fuel control dial between Low idle (MIN) position and
High idle (MAX) position, soot is accumulated much and action
level monitor “L03” may be displayed. However, this does not
indicate abnormality.
After performing manual stationary regeneration, turn the fuel
control dial to a point above the midpoint between Low idle
(MIN) position and High idle (MAX) position to continue the op-
eration.
When the degree of emergency is low
• If KDPF soot accumulation caution lamp (2) lights up in
yellow (action level (3): “L01”), screen (A) is displayed first.
• The action level goes out 2 seconds after and the screen
changes to standard screen (B).
• If the lock lever is set to LOCK position or all the work
equipment control levers are set in NEUTRAL, the screen
changes to “Aftertreatment Devices Regeneration” screen
(C) after 3 seconds only the first time. If the manual sta-
tionary regeneration is not performed, the screen returns
to standard screen (B) after 30 seconds.
Then, if the accumulated soot does not decrease, “After-
treatment Devices Regeneration” screen (C) is displayed
for 30 seconds every 2 hours.
• If KDPF soot accumulation caution lamp (2) lights up in
yellow, stop the machine in a safe place after finishing the
work and perform the manual stationary regeneration.
OPERATION
EXPLANATION OF COMPONENTS
3-115
Summary of Contents for PC360LC-11
Page 2: ......
Page 22: ......
Page 76: ......
Page 344: ......
Page 425: ...SPECIFICATIONS 5 1 ...
Page 429: ...PC360NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Page 430: ......
Page 450: ...PC360LC 11 2 Piece Boom PC360NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 20 ...
Page 457: ...ATTACHMENTS AND OPTIONS 17M LONG REACH BOOM AND ARM 6 27 ...
Page 465: ...ATTACHMENTS AND OPTIONS SUPER LONG FRONT BOOM AND ARM 6 35 ...
Page 499: ...REPLACEMENT PARTS 7 1 ...
Page 515: ......