Clean the outer element in the following procedure.
1.
Open the door at the rear right side of the machine, re-
move hooks (2) (3 places) and remove cover (3).
2.
Hold the outer element (5), rock it lightly up and down and
to the right and left, and pull the element out.
3.
When outer element (5) is removed, check that the inner
element does not come out of position and is not at an an-
gle.
If it is at an angle, push it straight to the bottom with your
hand.
4.
After removing outer element (5), cover the inner element
(6) with a clean cloth or tape to prevent dirt or dust from
entering.
5.
Clean dusts in inside and on cover (3) of air cleaner body (7) by using a clean cloth or brush.
6.
If any dust is attached to vacuator valve (4) installed to
cover (3), remove it.
7.
When the outer element has been cleaned 6 times or used
for 1 year, replace it.
• When the element needs to be replaced
Replace the inner and outer elements with new ones.
For details, see METHOD FOR REPLACING ELE-
MENT.
• When the element does not need to be replaced
Clean the outer element. Continue the cleaning proce-
dure.
8.
Blow dry compressed air (Max. 0.2 MPa{2.1 kg/cm
2
}) from
the inside of the outer element along the pleats.
9.
Blow along the pleats from the outside, then blow again
from the inside.
MAINTENANCE PROCEDURE
MAINTENANCE
4-16
Summary of Contents for PC360LC-11
Page 2: ......
Page 22: ......
Page 76: ......
Page 344: ......
Page 425: ...SPECIFICATIONS 5 1 ...
Page 429: ...PC360NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Page 430: ......
Page 450: ...PC360LC 11 2 Piece Boom PC360NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 20 ...
Page 457: ...ATTACHMENTS AND OPTIONS 17M LONG REACH BOOM AND ARM 6 27 ...
Page 465: ...ATTACHMENTS AND OPTIONS SUPER LONG FRONT BOOM AND ARM 6 35 ...
Page 499: ...REPLACEMENT PARTS 7 1 ...
Page 515: ......