Measurement of quantity of iron particles
A PQI (Particle Quantifier Index) measuring instrument is used
for measuring the quantity of iron particles of 5 μm or more, en-
abling early detection of failures.
Others
Measurements are made of items such as the ratio of water, coolant, and fuel in the oil, and dynamic viscosity, if
necessary, to enable a highly precise diagnosis of the machine and the components' condition.
Oil sampling interval
500 hours
Precautions when sampling
• Make sure that the oil is well mixed before sampling.
• Perform sampling at regular fixed intervals.
• Do not perform sampling on rainy or windy days when water or dust can get into the oil.
For further details of KOWA, contact your Komatsu distributor.
STORE OIL AND FUEL
• Keep oil and fuel indoors to prevent any water, dirt, or other impurities from getting in.
• When keeping drum cans for a long period, lay the drums so that the filler ports of the drums are located in
the lower part of the side to prevent moisture from being sucked in. If drums have to be stored outside, cov-
er them with a waterproof sheet or take other measures to protect them.
• To prevent any change in quality during long-term storage, be sure to use in the order of first in - first out
(use the oldest oil or fuel first).
STORE DEF
• Completely seal up its container for storage. Only open containers in a well-ventilated area.
• When storing DEF, avoid direct sunlight. Always use the original container. Make sure that transfer equip-
ment and tank must meet DEF compatible material specification. If DEF is stored in an iron or aluminum
container, toxic gas may develop and a chemical reaction may corrode the container.
• The relationship between the upper limit of storage temperature and the storage period of DEF is shown in
the table.
Temperature of storage area
Storage period
Max.10 °C
Up to 36 months
Max.25 °C
Up to 18 months
Max.30 °C
Up to 12 months
Max.35 °C
Up to 6 months
*: Do not store DEF in the temperature of 35 °C or above.
FILTER
• Filters are extremely important safety parts. They prevent impurities in the oil, fuel, and air circuits from en-
tering important equipment and causing problems. Replace all filters periodically. For details, see Operation
and Maintenance Manual.
However, when working in severe conditions, replace the filters at shorter intervals according to the oil and
fuel (sulfur content) being used.
OUTLINE OF MAINTENANCE
MAINTENANCE
4-8
Summary of Contents for PC700LC-11
Page 2: ......
Page 23: ...LOCATION OF SAFETY LABELS 5 SAFETY SAFETY LABELS 2 3...
Page 66: ......
Page 316: ......
Page 396: ......
Page 397: ...SPECIFICATIONS 5 1...
Page 401: ...For 7 6m Boom SPECIFICATIONS SPECIFICATIONS 5 5...
Page 402: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Page 426: ......
Page 427: ...REPLACEMENT PARTS 7 1...
Page 434: ......