2.
Select breaker mode “B” with function switches “F1” or
“F2” or “F5”.
3.
While breaker mode “B” is selected, press function switch
“F4” or leave it as it is for 5 seconds.
Working mode is set to breaker mode “B”, and the screen
returns to the standard screen.
REMARK
To return to the standard screen without changing the
working mode, press function switch “F3”.
ADJUST BREAKER OIL FLOW RATE
• Breaker flow rate can be adjusted in 15 levels (“15” to “1”).
“15” is the maximum flow rate and “1” is the minimum flow rate.
Approximately 5 ℓ/min per level can be changed.
• For the adjustment method of breaker flow rate, see “BREAKER SETTING”.
METHOD FOR OPERATING BREAKER
k
k
WARNING
If you do not perform breaker operation or 2-way attachment operation, set the working mode to normal
mode.
When the working mode is selected, if you press 1st-line attachment proportional switch or breaker op-
eration switch by mistake, this may lead to serious personal injury or death.
1.
Check that the working mode is set to the breaker mode B
on the machine monitor.
2.
Turn the fuel control dial to High idle (MAX) position, and
return it a little bit.
Set the engine output at 80 % position.
RKA64090
HANDLE MACHINE READY FOR INSTALLATION OF ATTACHMENT
ATTACHMENTS AND OPTIONS
6-22
WENAM00241
Summary of Contents for PC80MR-5E0
Page 2: ......
Page 12: ...Do not repeatedly handle and lift loads VIBRATION LEVELS FOREWORD 1 10 WENAM00241...
Page 70: ...GENERAL VIEW MACHINE EQUIPMENT NAME RKA67920 GENERAL VIEW OPERATION 3 2 WENAM00241...
Page 76: ...11 Fusible link 12 Ashtray if equipped 13 Tool boxes GENERAL VIEW OPERATION 3 8 WENAM00241...
Page 343: ...SPECIFICATIONS 5 1 WENAM00241...
Page 394: ...WENAM00241...
Page 395: ...REPLACEMENT PARTS 7 1 WENAM00241...
Page 411: ......
Page 412: ......