be fixed to low idle to disable practical machine operation. If the system advances to “Severe Inducement”, uti-
lize “Temporary Restoration from Inducement” immediately.
Procedure to activate “Temporary Restoration from Inducement”.
1.
Press F6 to display the “SCR Information” screen when
the Standard screen is on, only when the Urea SCR sys-
tem is in “Severe Inducement”.
2.
Press F6 to display the menu windows popping up in the
bottom half of the “SCR Information”.
The menu windows popping up in the bottom half of the
“SCR Information” screen alternate every 15 seconds as
shown in the graphics A and B.
3.
Press F6 while the pop-up menu screen B is displayed.
The “Engine power Recovery” window will be displayed.
If F6 is not pressed for 30 seconds, “ Standard Screen” will
be displayed, and start again by pressing F6.
The remaining number of operations of Temporary Resto-
ration from inducement is displayed in the column (1) of
the pop-up menu window B.
RKA63410
OPERATION
EXPLANATION OF COMPONENTS
3-145
WENAM00130
Summary of Contents for PW118MR-11
Page 2: ......
Page 9: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVEL 1 7 WENAM00130...
Page 22: ...WENAM00130...
Page 25: ...LOCATION OF SAFETY LABELS RKA64590 SAFETY SAFETY LABELS 2 3 WENAM00130...
Page 72: ...WENAM00130...
Page 74: ...GENERAL VIEW MACHINE EQUIPMENT NAME RKA61930 GENERAL VIEW OPERATION 3 2 WENAM00130...
Page 77: ...CONTROLS AND GAUGES NAMES RKA62690 OPERATION GENERAL VIEW 3 5 WENAM00130...
Page 168: ...SWITCHES RKA63060 EXPLANATION OF COMPONENTS OPERATION 3 96 WENAM00130...
Page 328: ...WENAM00130...
Page 412: ...WENAM00130...
Page 413: ...SPECIFICATIONS 5 1 WENAM00130...
Page 445: ...REPLACEMENT PARTS 7 1 WENAM00130...
Page 461: ......
Page 462: ......