4.
Press F6 while the “Engine power Recovery” window is
displayed.
Temporary Restoration from Inducement is activated and
engine power deration is relieved to the deration of “Mild
Inducement” for the maximum of 30 minutes as long as
there is sufficient remaining time to “Final Inducement”.
Note that whenever Inducement advances to “Final In-
ducement” Temporary Restoration from Inducement will be
turned off.
The remaining time (Minutes and Seconds) of “Temporary
Restoration from Inducement” is displayed in the column
(2) on the “SCR Information” screen.
If it is decided NOT to activate “Temporary Restoration from Inducement” after having progressed to the “Engine
Power Recovery” window, follow the steps explained in this section.
To deactivate “Temporary Restoration from Inducement” function.
1.
Press F5 while the “Engine Power Recovery” window is
displayed.
This procedure is split from procedure 4 in “Temporary Re-
storation from Inducement”.
“SCR Information” screen is displayed.
EXPLANATION OF COMPONENTS
OPERATION
3-146
WENAM00130
Summary of Contents for PW118MR-11
Page 2: ......
Page 9: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVEL 1 7 WENAM00130...
Page 22: ...WENAM00130...
Page 25: ...LOCATION OF SAFETY LABELS RKA64590 SAFETY SAFETY LABELS 2 3 WENAM00130...
Page 72: ...WENAM00130...
Page 74: ...GENERAL VIEW MACHINE EQUIPMENT NAME RKA61930 GENERAL VIEW OPERATION 3 2 WENAM00130...
Page 77: ...CONTROLS AND GAUGES NAMES RKA62690 OPERATION GENERAL VIEW 3 5 WENAM00130...
Page 168: ...SWITCHES RKA63060 EXPLANATION OF COMPONENTS OPERATION 3 96 WENAM00130...
Page 328: ...WENAM00130...
Page 412: ...WENAM00130...
Page 413: ...SPECIFICATIONS 5 1 WENAM00130...
Page 445: ...REPLACEMENT PARTS 7 1 WENAM00130...
Page 461: ......
Page 462: ......