MAINTENANCE
SERVICE PROCEDURE
PW160-7H VEAM390100
249
3.
Remove any dirt or dust that is accumulated in the evacuator
valve installed to cover.
4.
Direct dry compressed air (less than 0.69 MPa (7 kgf/cm
²
) to
the outer element from inside along its folds, then direct it
from outside along its folds and again from inside.
❍
Remove one seal from the element whenever the ele-
ment has been cleaned.
❍
Replace the outer element which has been cleaned 5
times repeatedly or used throughout a year. Replace the
inner element at the same time.
❍
Replace both inner and outer elements when the monitor
lamp (H) lights up soon after installing the cleaned outer
element even though it has not been cleaned 5 times.
❍
When replacing the element, new stick-on-seal is packed
in the same box as the element. Stick the seal in the posi-
tion.
5.
Remove the cloth or tape cover installed in Step 3.
6.
If small holes or thin cracks are found on the element when it
is checked by shining a light through it after cleaning, replace
the element.
NOTICE
●
When cleaning the element, do not hit or beat it against
anything.
●
Do not use an element whose folds or gasket or seal are
damaged.
Evacuator valve
Summary of Contents for PW160-7H
Page 2: ......
Page 3: ...PW160 7H VEAM390100 3 FOREWORD ...
Page 12: ...LOCATIONS OF PLATES TABLE TO ENTER SERIAL NO AND DISTRIBUTOR FOREWORD 12 PW160 7H VEAM390100 ...
Page 18: ...18 PW160 7H VEAM390100 ...
Page 220: ...TROUBLESHOOTING OPERATION 220 PW160 7H VEAM390100 ...
Page 305: ...PW160 7H VEAM390100 305 SPECIFICATIONS ...
Page 307: ...SPECIFICATIONS SPECIFICATIONS PW160 7H VEAM390100 307 1 PIECE BOOM ...
Page 308: ...SPECIFICATIONS SPECIFICATIONS 308 PW160 7H VEAM390100 2 PIECE BOOM ...
Page 345: ......