Precautions for operation
SAFETY
Battery
2-26
Starting with booster cables
0.
If any mistake is made in the method of connecting the booster
cables, it may cause the battery to explode, so always do as
follows:
When starting with a booster cable, carry out the starting
operation with two workers (one worker sitting in the opera-
tor's seat and the other working with the battery).
When starting from another machine, do not allow the two
machines to touch.
When connecting the booster cables, turn the starting
switch OFF for both the normal machine and problem
machine. There is a hazard that the machine will move
when the power is connected.
Be sure to connect the positive (+) cable first when installing
the booster cables. Disconnect the negative (-) cable
(ground side) first when removing them.
When removing the booster cables, be careful not to let the
booster cable clips touch each other or to let the clips touch
the machine.
Always wear safety goggles and rubber gloves when start-
ing the engine with booster cables.
When connecting a normal machine to a problem machine
with booster cables, always use a normal machine with the
same battery voltage as the problem machine.
For details of the starting procedure when using booster
cables, see “Starting engine with booster cable on page 3-
110“ in the OPERATION section.
Summary of Contents for WA250PT-5H
Page 2: ......
Page 3: ...FOREWORD 11...
Page 16: ...Contents FOREWORD 1 14...
Page 24: ...SAFETY 2 2...
Page 58: ...Precautions with tires SAFETY Precautions when storing tires 2 36...
Page 60: ...OPERATION 3 2...
Page 233: ...TECHNICAL DATA 45...
Page 235: ...TECHNICAL DATA Technical data 5 3...
Page 250: ...Central lubrication system ATTACHMENTS OPTIONS 6 14...
Page 251: ...INDEX 67...
Page 252: ...INDEX 7 2...
Page 255: ...Index 7 5...