SERVICE PROCEDURE
MAINTENANCE
4-46
CLEAN ELEMENT IN AIR CONDITIONER RECIRCULATION FILTER
4
1.
Loosen knob (1), remove filter inspection cover (2), then
open filter inspection cover (3).
2.
Pull out filters (4) and (5) in the direction of the arrow.
3.
Clean with compressed air in the same way as for the fresh
air filter.
If the filter is extremely dirty, rinse it in water.
After rinsing the filter, dry it completely before installing it
again.
LUBRICATING
4
NOTICE
On jobsites where there is a lot of heavy-duty work, or on jobsites where operations are carried out contin-
uously for more than eight hours, reduce the greasing interval and carry out greasing more frequently.
1.
Put the work equipment horizontally in contact with the
ground, then stop the engine.
2.
Using a grease pump, pump in grease through the grease
fittings marked by the arrows.
3.
After greasing, wipe off any old grease that was pushed
out.
(1) Bucket pin (2 places)
(2) Bucket link pin (2 places)
Summary of Contents for WA320-5H
Page 2: ...FOREWORD 11...
Page 17: ...CONTENTS FOREWORD 1 16...
Page 23: ...CE CONFORMING EQUIPMENT FOREWORD 1 22...
Page 24: ...SAFETY 12...
Page 25: ...SAFETY 2 2...
Page 60: ...OPERATION 13...
Page 181: ...TROUBLESHOOTING OPERATION 3 122...
Page 182: ...MAINTENANCE 14...
Page 243: ...SERVICE PROCEDURE MAINTENANCE 4 62...
Page 244: ...TECHNICAL DATA 15...
Page 246: ...TECHNICAL DATA TECHNICAL DATA 5 3...
Page 248: ...ATTACHMENTS OPTIONS 16...
Page 313: ...CENTRAL LUBRICATION SYSTEM ATTACHMENTS OPTIONS 6 66...
Page 314: ...INDEX 17...
Page 315: ...INDEX 7 2...
Page 318: ...NOTES 18...
Page 319: ...NOTES NOTES 8 2 NOTES 8...
Page 320: ...NOTES NOTES 8 3...
Page 321: ...2003 Komatsu Hanomag GmbH All Rights Reserved Printed in Europe 10 2003...