3.
Pull air cleaner pull-out jig (3) in a pull-out posture shown
in the figure and pull out outer element (4).
When pulling out the element, use the air cleaner pull-out
jig, hold the handrail tight in one hand, and put your feet on
the step to support your body.
NOTICE
Never remove inner element (5). Dusts may enter,
causing the engine failure.
4.
Clean the inside of the air cleaner body, cover (2) and va-
cuator valve (6).
NOTICE
Do not clean and reuse the inner element. When replacing the outer element, replace the inner element
with new one at the same time.
When cleaning the element, do not tap it or hit it against something.
Do not use the element with damaged pleats or a damaged gasket or seal.
Wrap an unused element and keep it in a dry place.
5.
Blow dry compressed air (Max. 0.2 MPa {2.1 kg/cm
2
}) from
the inside of the outer element along the pleats.
6.
Blow along the pleats from the outside, then blow again
from the inside.
MAINTENANCE
MAINTENANCE PROCEDURE
4-17
Summary of Contents for WA480-8
Page 2: ......
Page 19: ...Distributor name Address Phone Fax Service personnel FOREWORD PRODUCT INFORMATION 1 17...
Page 29: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 3...
Page 159: ...SWITCHES 1 ECSS switch 2 Front working lamp switch OPERATION EXPLANATION OF COMPONENTS 3 91...
Page 302: ...Securing position Fixing angle A 61 B 53 C 33 D 38 TRANSPORTATION OPERATION 3 234...
Page 324: ......
Page 397: ...Viewed from the rear side of the machine MAINTENANCE MAINTENANCE PROCEDURE 4 73...
Page 402: ......
Page 403: ...SPECIFICATIONS 5 1...
Page 406: ......
Page 422: ......
Page 423: ...REPLACEMENT PARTS 7 1...
Page 439: ......