Operation
3.3 Operation
WA500-6H – VEAM430100
3-127
Cancelling raised remote boom positioner
Set the lift arm control lever to the HOLD position and keep the
top of the remote positioner raise/lower set switch pressed for at
least 1 second. The buzzer will emit a long sound, the stop posi-
tion is reset, and the lamp inside the switch goes out.
When it has been reset and the lift arm control lever is set to the
detent position, if the lift arm is raised to near the maximum
height and it returns from the detent position to the HOLD posi-
tion, the lift arm operation will stop.
Operating lower remote boom positioner
1. Set the lift arm to the desired stop position between a point
below horizontal and a point approx. 300 mm (11.8 in) above
the ground surface.
(If it is less than 300 mm (11.8 in) from the ground, the stop
position cannot be set.)
2. Operate the lift arm control lever to the HOLD position and
press the top of the remote positioner raise/lower set switch.
The buzzer will emit short sounds, the position is set, and
the lamp inside the switch lights up.
Method of checking actuation
z
Raise the lift arm above horizontal, operate the lift arm con-
trol lever to the FLOAT position, then release the lever.
REMARK
If the lift arm is below horizontal and the lift arm control lever is
set to the FLOAT position, the lift arm is only set to FLOAT and it
does not automatically stop.
z
The lift arm will go down, and when the lift arm control lever
returns from the FLOAT position to the HOLD position, the
lift arm operation will stop.
Cancelling lower remote boom positioner
Set the lift arm control lever to the HOLD position and keep the
bottom of the remote positioner raise/lower set switch pressed
for at least 1 second. The buzzer will emit a long sound, the stop
position is reset, and the lamp inside the switch goes out.
When it has been reset and the lift arm control lever is set to the
FLOAT position, the lift arm is set to FLOAT and it moves under
external force.
GK050138
Summary of Contents for WA500-6H
Page 2: ......
Page 3: ...Foreword WA500 6H VEAM430100 1 1 1 Foreword...
Page 26: ...1 7 CE Conforming equipment Foreword 1 24 WA500 6H VEAM430100...
Page 254: ...3 7 Troubleshooting Operation 3 188 WA500 6H VEAM430100...
Page 344: ...4 9 Service procedure Every 12000 hours service Maintenance 4 90 WA500 6H VEAM430100...
Page 345: ...Technical Data WA500 6H VEAM430100 5 1 5 Technical Data...
Page 347: ...Technical Data 5 1 Technical data WA500 6H VEAM430100 5 3 GK032301 A B H I G C E F D...
Page 352: ...5 4 Limit values for slopes Technical Data 5 8 WA500 6H VEAM430100...
Page 401: ...Index WA500 6H VEAM430100 7 1 7 Index...
Page 407: ...Notes WA500 6H VEAM430100 8 1 8 Notes...
Page 408: ...Notes 8 2 WA500 6H VEAM430100...
Page 409: ...Notes WA500 6H VEAM430100 8 3...
Page 410: ...Notes 8 4 WA500 6H VEAM430100...
Page 411: ...Notes WA500 6H VEAM430100 8 5...
Page 412: ...Notes 8 6 WA500 6H VEAM430100...