4.6 Other troubles
Troubleshooting
4-16
WA70-7 – VENAM02003
*) These tasks should be performed by the distributor.
*) These tasks should be performed by the distributor.
Hydrostatic drive unit overheated
Purge valve is not working properly
(purge quantity too low)
Check the supply pressure *)
Repair and inspect the purge
valve *)
Hydraulic oil cooler (cooling sur-
faces, fins) is dirty
Clean the hydraulic oil cooler
(cooling surfaces, fins)
The fan is not working properly
Check the fan drive *)
Hydraulic filter is clogged (intake
quantity too small for the charge
pump)
Replace the filter element of the
hydraulic filter
The oil level in the hydraulic tank is
too low or too high
Correct the oil level in the hydraulic
tank
Abnormal noises
Oil level in the hydraulic tank is too
low
Fill up hydraulic oil
Air trapped in lines and units of the
hydraulic system (incorrect bleed-
ing)
Bleed the hydraulic system *)
HYDROSTATIC DRIVE UNIT (continued)
Fault
Cause
Remedy
WORK EQUIPMENT
Fault
Cause
Remedy
Lifting power too low
Hydraulic pump is defective
Directional valve (DBV) is defective
Cylinder is defective (leaks inside)
Repair the hydraulic pump*)
Check and adjust the DBV *)
Repair the cylinder *)
Lifting speed too slow
Rpm of diesel engine too low
Hydraulic pump is defective
Priority valve defective
Directional valve or pilot control
valve defective
Cylinder is defective (leaks inside)
Required charge pressure not
reached
Adjust speed *)
Repair the hydraulic pump*)
Repair the priority valve *)
Repair the valves *)
Repair the cylinder *)
Adjust the supply pressure *)
Air bubbles in the hydraulic oil
Wrong hydraulic oil quality
Refill with the prescribed hydraulic
oil
Oil level in the hydraulic oil tank is
too low
Fill up hydraulic oil
Cylinder movements are jerky.
Oil level in the hydraulic oil tank is
too low
Hydraulic pump is defective
Priority valve defective
Directional valve defective
Fill up hydraulic oil
Check the hydraulic pump; replace
if necessary *)
Check the priority valve; replace if
necessary *)
Check the directional valve;
replace if necessary *)
Summary of Contents for WA70-7
Page 2: ......
Page 3: ...Foreword WA70 7 VENAM02003 1 1 1 Foreword...
Page 23: ...Foreword 1 5 Table of contents WA70 7 VENAM02003 1 21 Blank for technical reason...
Page 28: ...1 7 Equipment Foreword 1 26 WA70 7 VENAM02003...
Page 75: ...Operation WA70 7 VENAM02003 3 1 3 Operation...
Page 114: ...3 2 Descriptions of the individual elements Operation 3 40 WA70 7 VENAM02003 Fuse allocation...
Page 185: ...Troubleshooting WA70 7 VENAM02003 4 1 4 Troubleshooting...
Page 203: ...Maintenance WA70 7 VENAM02003 5 1 5 Maintenance...
Page 277: ...Technical data WA70 7 VENAM02003 6 1 6 Technical data...
Page 283: ...Special equipment attachments WA70 7 VENAM02003 7 1 7 Special equipment attachments...
Page 291: ...Index WA70 7 VENAM02003 8 1 8 Index...
Page 296: ...8 1 Index Index 8 6 WA70 7 VENAM02003...
Page 297: ...Notes WA70 7 VENAM02003 9 1 9 Notes...
Page 298: ...Notes 9 2 WA70 7 VENAM02003...
Page 299: ...Notes WA70 7 VENAM02003 9 3...
Page 300: ...Notes 9 4 WA70 7 VENAM02003...
Page 301: ...Notes WA70 7 VENAM02003 9 5...
Page 302: ...Notes 9 6 WA70 7 VENAM02003...