5.8 Maintenance procedure
Maintenance
Maintenance every 250 service hours
WA70-7 – VENAM02003
5-45
5.8.8
Maintenance every 250 service hours
Also perform all maintenance tasks scheduled to be carried out
every 10 and every 50 service hours.
Service brake – check the brake pads
WARNING
Danger of accidents! If the brake oil level is too low, the service
brake might fail.
ATTENTION
Danger of accidents! Using commercially available brake
fluid may reduce the performance of the brake system.
Only fill with the specified oil. Do not use brake fluid! Keep
extremely clean!
1. For maintenance work, park and secure the machine as
described in chapter 5.1 “Maintenance guide” (5-2).
2. Check brake disc and brake pads for wear and damages.
3. Check the brake oil level.
Summary of Contents for WA70-7
Page 2: ......
Page 3: ...Foreword WA70 7 VENAM02003 1 1 1 Foreword...
Page 23: ...Foreword 1 5 Table of contents WA70 7 VENAM02003 1 21 Blank for technical reason...
Page 28: ...1 7 Equipment Foreword 1 26 WA70 7 VENAM02003...
Page 75: ...Operation WA70 7 VENAM02003 3 1 3 Operation...
Page 114: ...3 2 Descriptions of the individual elements Operation 3 40 WA70 7 VENAM02003 Fuse allocation...
Page 185: ...Troubleshooting WA70 7 VENAM02003 4 1 4 Troubleshooting...
Page 203: ...Maintenance WA70 7 VENAM02003 5 1 5 Maintenance...
Page 277: ...Technical data WA70 7 VENAM02003 6 1 6 Technical data...
Page 283: ...Special equipment attachments WA70 7 VENAM02003 7 1 7 Special equipment attachments...
Page 291: ...Index WA70 7 VENAM02003 8 1 8 Index...
Page 296: ...8 1 Index Index 8 6 WA70 7 VENAM02003...
Page 297: ...Notes WA70 7 VENAM02003 9 1 9 Notes...
Page 298: ...Notes 9 2 WA70 7 VENAM02003...
Page 299: ...Notes WA70 7 VENAM02003 9 3...
Page 300: ...Notes 9 4 WA70 7 VENAM02003...
Page 301: ...Notes WA70 7 VENAM02003 9 5...
Page 302: ...Notes 9 6 WA70 7 VENAM02003...