KT-70E / KT-90E / KT-70SE User Manual
Page 21 of 59
24 April 2018
3.2.5.
Notes on special types of hazard
Electric power
In case of faults in the electrical power supply, the system must be switched off immedi-
ately!
Work on electrical systems or equipment must be per local codes, and carried out by a
qualified electrician or by instructed persons under the direction and supervision of a
qualified electrician.
The electrical equipment must be regularly inspected / checked. Defects such as loose
connections or scorched cables must be rectified immediately.
Pneumatics
All lines, hoses and fittings must be checked regularly for leaks and externally visible
damage! Damage must be eliminated immediately! Splashed oil may cause injury and
fire.
Insure that the system and any hoses are depressurized before starting any repair work!
Compressed air lines must be professionally installed and mounted! Do not interchange
connections! Fittings, length and quality of the hoses must comply with the requirements.
Hazard statements for dealing with the filter and pressure vessels
Never remove reservoir cap or pipe connection parts under pressure.
The KT-70E / KT-90E has a container (filter) for dynamic load. This pressure vessel may
be operated under varying operating pressure. The pressure may vary between the atmos-
pheric and the maximum operating pressure.
We recommend replacing aluminum containers at least every 15 years.
This measure should observe to ensure your own safety and that of your employees and
customers unconditionally and obey!
Check your pressure vessels regularly inside and outside for damage from corrosion.
Residual Risk Zones
DANGER: In some compressor zones there remain residual risks that were not possible
to eliminate at the design stage or for which safety guards could not be provided without
compromising the functionality of the compressor. To prevent accidents all operators
must be aware of the residual risks on this compressor.
There is a danger of polluting the intake air due to the possibility of mixing exhaust fumes
or lubricating oil vapors with the compressed air being produced.
Summary of Contents for KT-70E
Page 49: ...KT 70E KT 90E KT 70SE User Manual Page 49 of 59 24 April 2018 Figure F First Stage Cylinder...
Page 51: ...KT 70E KT 90E KT 70SE User Manual Page 51 of 59 24 April 2018 Figure 8 Third Stage Cylinder...
Page 53: ...KT 70E KT 90E KT 70SE User Manual Page 53 of 59 24 April 2018 Figure 10 Filter Housing...
Page 54: ...KT 70E KT 90E KT 70SE User Manual Page 54 of 59 24 April 2018 Figure K Casing...