KT-70E / KT-90E / KT-70SE User Manual
Page 34 of 59
24 April 2018
8.2.1.4.
Condensate Drain
1.
Drain the condensate after
every 15 to 25 minutes of
operation
The compressor condensate
consists of a mixture of water
and compressor oil. Cloth and
condensate must be disposed of
in accordance with local laws
and regulations to ensure ap-
propriate places.
Opening the condensate drain
plug too quickly may cause
icing in the condensate drain
and potentially dangerous air
velocities. Therefore, open
the drain extremely cau-
tiously.
8.2.1.5.
Turning off
For units configured with the
Auto Shut-Off, compressor
will stop when target pressure
is reached
1.
Upon reaching the set air
pressure, switch to “O” or
“OFF”
2.
The compressor stops.
.