KT-70E / KT-90E / KT-70SE User Manual
Page 35 of 59
24 April 2018
8.2.1.6.
Complete the Filling process
1.
Close the filling valve (on
compressor, fill valve or
on target cylinder)
2.
Slowly open the Conden-
sate Drain and drain the
condensate. Bleed resid-
ual pressure in fill hose or
system.
3.
Remove the pressure ves-
sel at the filling valve
8.3.
Filter
•
ONLY the filter cartridges provided by Komptec may be used!
•
Filter part numbers are listed in section 10.1
•
Modifying the filter system in any way is prohibited!
•
Use of non-authorized filter materials, even if they are
used by other filter manufacturers,
may lead to severe impairment of filter efficiency, including total loss of filter effect.
•
Filters must be changed at least once per year
8.3.1.
Breathing Air Filter
Filters configured for Breathing Air usage include both molecular sieve and activated
carbon materials. The filter lifetime is 60 m
3
of air at 30
°
C. These filter lifetimes
have been specified to be in compliance with DIN EN12021.
Filter Change Interval
Capacity
Temperature
70 LPM
90 LPM
30
°
C
13 hours
10 hours
8.3.2.
Non-Breathing Air Filter
Filters configured for Non-Breathing Air usage replace the activated carbon with ad-
ditional molecular sieve material. The filter lifetime is 90 m
3
of air at 30
°
C. Examples
of applications where the Non-Breathing Air Filter can be considered include shooting
sports and industrial / construction applications.
Summary of Contents for KT-70E
Page 49: ...KT 70E KT 90E KT 70SE User Manual Page 49 of 59 24 April 2018 Figure F First Stage Cylinder...
Page 51: ...KT 70E KT 90E KT 70SE User Manual Page 51 of 59 24 April 2018 Figure 8 Third Stage Cylinder...
Page 53: ...KT 70E KT 90E KT 70SE User Manual Page 53 of 59 24 April 2018 Figure 10 Filter Housing...
Page 54: ...KT 70E KT 90E KT 70SE User Manual Page 54 of 59 24 April 2018 Figure K Casing...