KT-70E / KT-90E / KT-70SE User Manual
Page 38 of 59
24 April 2018
Tripped circuit breaker
Reset circuit breaker mounted
above electric motor
Engine failure
Temperature under +10°C
Warm up compressor to +10°C.
System does not turn on
Interrupted power supply
Check plug and cable
Check fuse or circuit breaker
Engine failure
Replace motor
Fuse or circuit breaker blows
when engine turned on
Wrong size fuses / circuit
breaker, or time delay not
correct
Replace fuses, check with a li-
censed electrician
Short circuit in electrical sys-
tem
Have it checked by a licensed elec-
trician
Compressor becomes noisy
v-belt not tightened
Tighten belts
Gas motor does not start
See manual for Gas Motor
Contact the manufacturer for issues not listed.