Komptec GmbH. KT-90A User Manual
Page 26 of 52
v1.0a; 8 May 2016
7.
Start-up
To avoid damage or serious injury during startup of the compressor, the following points
must be observed:
−
If the ambient temperature is below +10 °C, follow the instruction is section 6.3
−
The commissioning of the compressor may only be carried out by qualified staff in
compliance with the safety.
−
Check before the first start that all tools and foreign objects were removed from the
compressor.
−
For three-phase motors, check the motor rotation direction prior to operation.
−
Also read the chapter "General safety instructions".
7.1.
Checks before initial Start-up
F
Remove all packing used in transport
F
Check that all screws and bolts are secure
F
Check all cables and connectors.
F
Check the oil level
The compressor must be filled with at least 50% of the specified amount
of oil.
F
Check filter system for damage and completeness. Insert the filter car-
tridge.
All protective devices must be correctly fitted.
i