8.2.1.4.
Condensate Drain
1.
Drain the condensate after
every 10 minutes of opera-
tion from both intermediate
and final condensate drains.
The compressor condensate
consists of a mixture of water
and compressor oil. Cloth and
condensate must be disposed of
in accordance with local laws
and regulations to ensure ap-
propriate places.
Opening the condensate drain
plug too quickly may cause
icing in the condensate drain.
Therefore, open the drain ex-
tremely cautiously.
8.2.1.5.
Turning off
1.
Manually turn off the com-
pressor by switching “off”
Or, the Auto Shut Off will
turn off the power when the
specified pressure is obtained
(200 bar or 300 bar)
i