Table 11. FAULT CODES
Code
Fault
Possible cause
Suggested solution
Resetting
1
Overcurrent
• Motor failed
• Short circuit in motor wiring
• Check/replace motor
• Check/repair motor wiring.
A
2
Overvoltage
• Too high supply voltage
• Braking resistor failed
• Break in braking resistor
wiring
• Measure supply voltage and
check hoist supply voltage
from hoist type plate
• Measure braking resistor
resistance
• Check braking resistor and
wiring visually
C
3
Earth Fault
• Short circuit in wiring
• Motor failed
• Check/repair wiring
• Check/replace motor
A
8
System Fault
• Internal fault
• Switch off supply voltage
• If problem recurs, replace
inverter
B
13
Under temperature
• Internal temperature too low
• Minimum operating
temperature is -30ºC
C
14
Overtemperature
• Internal heat sink
temperature too high
• Wait for unit cooling down
C
22
API
EEPROM
Checksum
• Internal parameter save error • Switch off supply voltage
• If problem recurs, replace
inverter
B
23
POW
EEPROM
Checksum
• Internal parameter save error • Switch off supply voltage
• If problem recurs, replace
inverter
B
24
Counter fault
• Internal counter error
• Switch off supply voltage
• If problem recurs, replace
inverter
B
25
API Microprocessor
Watchdog
• Internal watchdog error
• Switch off supply voltage
• If problem recurs, replace
inverter
B
26
POW
Microprocessor
Watchdog
• Internal watchdog error
• Switch off supply voltage
• If problem recurs, replace
inverter
B
34
Internal
Bus
Communication
• Internal bus error
• Switch off supply voltage
• If problem recurs, replace
inverter
B
35
Application Fault
• Internal application error
• Switch off supply voltage
• If problem recurs, replace
inverter
B
41
IGBT
Overtemperature
• Internal IGBT temperature
too high
• Wait for unit cooling down
C
52
Parameter Fault
• Wrong parameter setting.
P1,9 Drive Selection = 0
• Check parameter P1.9 Drive
Selection
C
020145en / Revision D / 2015-04-29
27/31
This document and the information contained herein, is the exclusive property of Konecranes Plc. and represents a non-public, confidential and proprietary trade secret that may not be
reproduced, disclosed to other parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Plc.
Copyright
©