Instruction manual SMV 10 600B – 60 1500B Publ. no. 6196.082 1117, Version 02
Presentation of the machine
VENTILATION
A = Heat
• (1) Temperature
• (2) Fan
B = AC:
• (1) Temperature
• (2) Fan
• (3) Recirculation
• (4) Cold
C = ACC:
• (1) Temperature
• (2) Fan (stepless)
• (3) Recirculation
• (4) Cold
Settings for different types of weather
• Warm weather with normal air humidity
– Open the fresh air intake
– Close the heat regulator
– Switch on the cooling and set the cold temperature to the
desired position.
• Very warm weather with high air humidity
– Close the fresh air intake
– Close the heat regulator
– Switch on the cooling and set the cold temperature to the
desired position.
• During autumn and early winter with high air humidity with
rain, slush and mist on the windows
– Switch on the cooling
– Open the fresh air intake
– Crank open a window so that the air can circulate in the cabin.
– Increase the heat if necessary.
• Cold weather in the winter
– Open the fresh air intake, switch off the cooling
– Set the heat to the desired position.
• Very cold weather with low air humidity
– Close the fresh air intake
– Switch off the cooling.
– Set the heat to the desired position.
• Winter during cold and dry periods with low degree of use
– Switch on the cooling and allow the compressor to work for
a few minutes once a week so that connections, seals etc. are
lubricated.