Kongsberg ACS500
System status
The following section shows how to find different aspects of the system status.
•
Checking communication between the Acoustic Command Unit and the Subsea
Control Unit
on page 48
•
Reading the system status information
on page 48
•
on page 49
•
on page 49
Checking communication between the Acoustic Command
Unit and the Subsea Control Unit
Purpose
This procedure explains how to check if there is communication between the surface
system and the subsea system.
Procedure
1
In the
Battery Status
section, tap
Read
.
2
Wait for reply from the SCU. If no response, try three times before continuing with
the next step. If you have communication, continue with normal valve operations.
3
Increase the power setting with one step at the time on both the ACU and the SCU.
See
Setting the telemetry power level for the ACU
on page 46 and
telemetry power level for the Subsea Control Unit
on page 47.
Check the communication by reading the battery status between each step. If
no response, try three times before continuing with the next step. If you have
communication, continue with normal valve operations.
4
Try the alternative SCU. Go back to lower power setting before you start. If
no response, try three times before continuing with the next step. If you have
communication, continue with normal valve operations.
5
Try the same steps with the alternative acoustic protocol and always start with a
lower setting both on the ACU and the SCU.
See
Changing between Cymbal and FSK
on page 47.
Reading the system status information
Purpose
This procedure explains how to read the system status information.
Procedure
1
Select the tab for the SCU you want to see.
2
In the
System Status
section, tap
Read
.
48
397128/C
Summary of Contents for ACS500
Page 1: ...INSTRUCTION MANUAL ACS500 Acoustic Control System Gisma testport system...
Page 2: ......
Page 15: ...ACS500 System with interface cables 397128 C 13...
Page 38: ...Kongsberg ACS500 ACU Computer buttons on page 37 User interface on page 38 36 397128 C...
Page 71: ...Simulation and test 397128 C 69...
Page 113: ...Drawing file Dunking transducer unit outline dimensions 397128 C 111...
Page 114: ...Kongsberg ACS500 Acoustic Command Unit outline dimensions 112 397128 C...
Page 115: ...Drawing file Subsea Control Unit outline dimensions 397128 C 113...
Page 116: ...Kongsberg ACS500 Subsea Control Unit arrangement 114 397128 C...
Page 117: ...Drawing file Subsea Control Unit bracket 397128 C 115...
Page 118: ...Kongsberg ACS500 TDR30V 34GT Subsea transducer outline dimensions 116 397128 C...
Page 119: ...Drawing file External quad battery unit for SCU outline dimensions 397128 C 117...
Page 120: ...Kongsberg ACS500 Simulator outline dimensions 118 397128 C...
Page 138: ...Kongsberg ACS500 Appendix A Type approval certificate 136 397128 C...
Page 139: ...Appendix A Type approval certificate 397128 C 137...
Page 140: ...Kongsberg ACS500 138 397128 C...
Page 141: ...Appendix A Type approval certificate 397128 C 139...
Page 142: ...Kongsberg ACS500 140 397128 C...
Page 148: ...2016 Kongsberg Maritime...