Kongsberg ACS500
Powering off the ACS500
Procedure
1
The SCU is powered off by opening the top end cap and removing the battery.
See
Opening the Subsea Control Unit
on page 78.
2
Press the
Power
button
D
to the OFF position, to turn off the ACU.
Tip
Tapping
Exit
on the touch screen only turns the computer off, the rest of the system
is still using battery power. Always use the power button to switch off the ACU.
Starting up the surface system
Purpose
This procedure shows how to start up the system.
Procedure
1
Place the ACU in a suitable location and open the lid by pressing the handle knobs
and pulling the handles towards you.
2
Turn on the ACU with the
Power
button
D
on the right hand side.
The system takes about 1.5 minutes to start up, continue with the cables while
the system starts.
3
Place the cable drum with the dunking transducer close to the ACU.
4
Prepare the dunking transducer for operation.
See
on page 30.
5
Pull out the cable and lower the transducer to a depth at least 10 meters below
the lowest draft of the platform/vessel.
6
Connect the transducer cable to the connector marked TD on the top right hand
side of the ACU.
7
The system is ready for use.
32
397128/C
Summary of Contents for ACS500
Page 1: ...INSTRUCTION MANUAL ACS500 Acoustic Control System Gisma testport system...
Page 2: ......
Page 15: ...ACS500 System with interface cables 397128 C 13...
Page 38: ...Kongsberg ACS500 ACU Computer buttons on page 37 User interface on page 38 36 397128 C...
Page 71: ...Simulation and test 397128 C 69...
Page 113: ...Drawing file Dunking transducer unit outline dimensions 397128 C 111...
Page 114: ...Kongsberg ACS500 Acoustic Command Unit outline dimensions 112 397128 C...
Page 115: ...Drawing file Subsea Control Unit outline dimensions 397128 C 113...
Page 116: ...Kongsberg ACS500 Subsea Control Unit arrangement 114 397128 C...
Page 117: ...Drawing file Subsea Control Unit bracket 397128 C 115...
Page 118: ...Kongsberg ACS500 TDR30V 34GT Subsea transducer outline dimensions 116 397128 C...
Page 119: ...Drawing file External quad battery unit for SCU outline dimensions 397128 C 117...
Page 120: ...Kongsberg ACS500 Simulator outline dimensions 118 397128 C...
Page 138: ...Kongsberg ACS500 Appendix A Type approval certificate 136 397128 C...
Page 139: ...Appendix A Type approval certificate 397128 C 137...
Page 140: ...Kongsberg ACS500 138 397128 C...
Page 141: ...Appendix A Type approval certificate 397128 C 139...
Page 142: ...Kongsberg ACS500 140 397128 C...
Page 148: ...2016 Kongsberg Maritime...