In case of hazardous events, the noxious gases are:
• Thionyl chloride (SOCl
2
)
• Sulphur dioxide (SO
2
)
• Hydrogen sulphide (H
2
S)
• Hydrogen chloride (HCl)
• Chlorine (Cl
2
)
For additional information about the cells inside the sealed battery pack, see the safety
data sheet provided by the cell manufacturer.
•
Manufacturer
: Saft
•
Cell type
: LSH 20
•
Manufacturer’s website
:
https://www.saftbatteries.com/
SECTION 4: First aid measures
The battery will release toxic fumes if burned or exposed to fire.
If subjected to gas from a burning battery, remove the source of contamination or move
yourself and any victims to fresh air. Seek medical advice.
•
Inhalation
: The chemicals are lung irritant. Avoid inhaling any vented gases. Remove
the victim and yourself from exposure. Rest and keep warm. If breathing is difficult,
seek emergency medical attention.
•
Skin contact
: The chemicals are skin irritant. Rinse immediately with copious amount
of water and soap for at least 15 minutes. Wipe immediately away excess material
with waterless hand cleaner. Remove contaminated clothing and wash it thoroughly
before reuse.
•
Eye contact
: The chemicals are eye irritant. Flush immediately with copious amount
of clear tepid water for at least 15 minutes.
•
Ingestion
: Exposure to the chemicals may cause tissue damage to throat and
gastro/respiratory tract if swallowed. If ingested, rinse mouth and surrounding area
with tepid water. Dilute by drinking plenty of water. Seek medical advice.
SECTION 5: Firefighting measures
The transponder is designed to withstand damage to the internal battery pack.
Non-flammable materials are used. In case of fire, move the battery away from fire area
if you can do it without compromising your own safety. Extreme mechanical abuse to
the battery may result in a ruptured seal and exposure.
1
If possible, move the battery and/or the transponder away from the fire.
Kongsberg cNODE Instruction Manual
Summary of Contents for cNODE Maxi
Page 1: ...Instruction Manual cNODE Maxi and Midi Transponders Medium Frequency 4000 metres ...
Page 2: ......
Page 69: ...322217 G 67 Differential inclinometer arrangement drawing About drawings ...
Page 70: ...68 322217 G Current meter arrangement drawing Kongsberg cNODE Instruction Manual ...
Page 98: ... 2019 Kongsberg Maritime ...